+7 (8635) 22-53-50, 22-53-51, 22-53-71
паравозик
Testing equipment
Catalog
02.01.13 Test station of the power transformer of the I-IV dimensions

02.01.13 Test station of the power transformer of the I-IV dimensions

The station is intended to test power transformers with capacity up to 5000 kVA with voltage up to 10 kV.
TECHNICAL DESCRIPTION
Power supply is provided from transformer substation, 400kVA 380V, 50Hz
Number of tested positions, 1
Three phase output testing voltage:,
- 50Hz, 0 - 6300V (Imax. 110A)
-100Hz, 0 - 800V (Imax 70A)
One phase output AC voltage, 0 - 35kV (Imax 1,5A)
Area of the test station, m2 40
OVERALL DIMENSIONS
Power rack 35kV, 1350x1050x2000
Control power rack 0,8kV, 1350x1050x2000
Electric generator, 700x1200x500
Power transformer, 1000x900x1300
Induction regulator, 1100x1100x1500
TECHNICAL DESCRIPTION OF MEASURING DEVICES:
DIGITAL MEGAOHMMETER E6-22
Precision rate, 1,5
Measuring resistance range, Ω 1 - 10 (7)
Nominal testing voltage, V 500, 1000, 2500
Max. current, mA not more than 5
DIGITAL MEASURING DEVICES PFP-1
Precision rate, 0,15
Measuring speed, measurement/sec 3
Monitoring time, msec less than 3
COMPLEXES FOR MEASURING ACTIVE RESISTANCE OF WINDINGS
Max. current through windings, A 10
Measuring resistance range, Om 0,001-10
Resistance accuracy, % 0,5

Fig.1. Equipment lay out
Back to section