Test station is intended to test AC asynchronous and synchronous electric motors after overhaul. Voltage of tested electric motor, kV: from 0.66 up to 6. Capacity of tested electric motor, kW: 100-400 250-1000. Equipment installed at the station provides the following trials: - measuring winding isolation resistance in relation to the machine body and between the winding. - Measuring resistance of windings under direct current in practically cold state. - Trials under increased frequency of rotation. - Electric stability testing of winding isolation in relation to machine body and between the windings. - Electric stability testing of winding interloop isolation. - determination of idle running current and losses; - determination of short circuit voltage and losses; - Determination of transformation ratio (for machines with phase rotor). - Idle running. - Determination of idle current for synchronous machines.
Call for price
TECHNICAL DESCRIPTION
Nominal supply voltage, V 380, 50Hz (400kVA)
Consumed current in settling conditions, A up to 630
Output regulated voltage, V 0 ÷ 650(Imax - 355A)
Output regulated voltage, V 0 ÷ 10000(Imax-50A)
Output regulated voltage (1 phase), kV 0 ÷ 27,5 (Imax - 1,5A)
Output regulated voltage of DC current, V 0 ÷ 100 (Imax – 300A)
Megaohmmeter output voltage, V 100, 500, 1000
Resistance winding measuring range, Mom 2 ÷ 200x10(6)
Number tested positions, pcs 1
Spindle height of tested electric motor, mm 280-630
Overall dimensions,
Rack No 1, mm/mass, kg 750x1650x2030/580
Rack No 2, mm/mass, kg 490x1220x1830/260
Rack No 3, mm/mass, kg 900x1040x1830/400
Rack No 4, mm/mass, kg 850x1040x1830/580
Induction regulator, mm/mass, kg 1380x1300x2000/2700
Frequency converter, mm/mass, kg 195x340x550/24
Test table, mm/mass, kg 1930x1890x500/820
Rack with wide, mm/mass, kg 740x700x1200/390
TECHNICAL DESCRIPTION OF MEASURING DEVICES:
DIGITAL MEGAOHMMETER E6-22:
Precision rate, 1,5
Measurement resistance range, Ω 1 - 10(7)
Nominal tested voltage, V 100, 500, 1000
Max. current, mA not more than 5
DIGITAL MEASURING DEVICES PFP-1:
Precision rate, 0,15
Measuring speed, measurement/sek 3
Monitoring time, msec less 300

Fig1. Equipment lay out.
Back to section